blob: 5566533d6444910973147e809931682ad36d3f34 [file] [log] [blame]
Adam Snaiderc4b3c192015-02-01 01:30:39 +00001#ifndef FRC971_ZEROING_ZEROING_H_
2#define FRC971_ZEROING_ZEROING_H_
3
Philipp Schrader41d82912015-02-15 03:44:23 +00004#include <cstdint>
Adam Snaiderc4b3c192015-02-01 01:30:39 +00005#include <vector>
Philipp Schrader41d82912015-02-15 03:44:23 +00006
Austin Schuh703b8d42015-02-01 14:56:34 -08007#include "frc971/control_loops/control_loops.q.h"
8#include "frc971/constants.h"
Adam Snaiderc4b3c192015-02-01 01:30:39 +00009
Adam Snaiderb4119252015-02-15 01:30:57 +000010// TODO(pschrader): Create an error API to flag faults/errors etc..
11//
12// TODO(pschrader): Flag an error if encoder index pulse is not n revolutions
13// away from the last one (i.e. got extra counts from noise, etc..)
14//
15// TODO(pschrader): Flag error if the pot disagrees too much with the encoder
16// after being zeroed.
17//
18// TODO(pschrader): Watch the offset over long periods of time and flag if it
19// gets too far away from the initial value.
20
Adam Snaiderc4b3c192015-02-01 01:30:39 +000021namespace frc971 {
22namespace zeroing {
23
24// Estimates the position with encoder,
25// the pot and the indices.
26class ZeroingEstimator {
27 public:
Austin Schuh703b8d42015-02-01 14:56:34 -080028 ZeroingEstimator(const constants::Values::ZeroingConstants &constants);
Austin Schuh703b8d42015-02-01 14:56:34 -080029
Adam Snaiderb4119252015-02-15 01:30:57 +000030 // Update the internal logic with the next sensor values.
31 void UpdateEstimate(const PotAndIndexPosition &info);
32
33 // Reset the internal logic so it needs to be re-zeroed.
34 void Reset();
35
36 // Returns true if the logic considers the corresponding mechanism to be
37 // zeroed. It return false otherwise. For example, right after a call to
38 // Reset() this returns false.
Austin Schuh703b8d42015-02-01 14:56:34 -080039 bool zeroed() const { return zeroed_; }
Adam Snaiderb4119252015-02-15 01:30:57 +000040
41 // Return the estimated position of the corresponding mechanism. This value
42 // is in SI units. For example, the estimator for the elevator would return a
43 // value in meters for the height relative to absolute zero.
44 double position() const { return pos_; }
45
46 // Return the estimated starting position of the corresponding mechansim. In
47 // some contexts we refer to this as the "offset".
48 double offset() const { return start_pos_; }
49
50 // Returns a number between 0 and 1 that represents the percentage of the
51 // samples being used in the moving average filter. A value of 0.0 means that
52 // no samples are being used. A value of 1.0 means that the filter is using
53 // as many samples as it has room for. For example, after a Reset() this
54 // value returns 0.0. As more samples get added with UpdateEstimate(...) the
55 // return value starts increasing to 1.0.
Austin Schuh703b8d42015-02-01 14:56:34 -080056 double offset_ratio_ready() const {
57 return start_pos_samples_.size() / static_cast<double>(max_sample_count_);
58 }
59
Adam Snaiderc4b3c192015-02-01 01:30:39 +000060 private:
Adam Snaiderb4119252015-02-15 01:30:57 +000061 // The estimated position.
62 double pos_;
Adam Snaiderc4b3c192015-02-01 01:30:39 +000063 // The distance between two consecutive index positions.
64 double index_diff_;
Adam Snaiderb4119252015-02-15 01:30:57 +000065 // The next position in 'start_pos_samples_' to be used to store the next
66 // sample.
Adam Snaiderc4b3c192015-02-01 01:30:39 +000067 int samples_idx_;
68 // Last 'max_sample_count_' samples for start positions.
69 std::vector<double> start_pos_samples_;
Adam Snaiderb4119252015-02-15 01:30:57 +000070 // The number of the last samples of start position to consider in the
71 // estimation.
Adam Snaiderc4b3c192015-02-01 01:30:39 +000072 size_t max_sample_count_;
Adam Snaiderb4119252015-02-15 01:30:57 +000073 // The estimated starting position of the mechanism. We also call this the
74 // 'offset' in some contexts.
75 double start_pos_;
Philipp Schrader030ad182015-02-15 05:40:58 +000076 // The absolute position of any index pulse on the mechanism. This is used to
77 // account for the various ways the encoders get mounted into the robot.
78 double known_index_pos_;
Philipp Schrader41d82912015-02-15 03:44:23 +000079 // Flag for triggering logic that takes note of the current index pulse count
80 // after a reset. See `index_pulse_count_after_reset_'.
81 bool wait_for_index_pulse_;
82 // After a reset we keep track of the index pulse count with this. Only after
83 // the index pulse count changes (i.e. increments at least once or wraps
84 // around) will we consider the mechanism zeroed.
85 uint32_t index_pulse_count_after_reset_;
Adam Snaiderb4119252015-02-15 01:30:57 +000086 // Marker to track whether we're fully zeroed yet or not.
87 bool zeroed_;
Adam Snaiderc4b3c192015-02-01 01:30:39 +000088};
89
Adam Snaiderb4119252015-02-15 01:30:57 +000090} // namespace zeroing
91} // namespace frc971
Adam Snaiderc4b3c192015-02-01 01:30:39 +000092
93#endif // FRC971_ZEROING_ZEROING_H_