| /* Copyright (c) FIRST 2008-2017. All Rights Reserved. */ |
| /* Open Source Software - may be modified and shared by FRC teams. The code */ |
| /* must be accompanied by the FIRST BSD license file in the root directory of */ |
| /* the project. */ |
| /*----------------------------------------------------------------------------*/ |
| |
| #include "AnalogTriggerOutput.h" |
| |
| #include "AnalogTrigger.h" |
| #include "HAL/HAL.h" |
| #include "WPIErrors.h" |
| |
| using namespace frc; |
| |
| /** |
| * Create an object that represents one of the four outputs from an analog |
| * trigger. |
| * |
| * Because this class derives from DigitalSource, it can be passed into routing |
| * functions for Counter, Encoder, etc. |
| * |
| * @param trigger A pointer to the trigger for which this is an output. |
| * @param outputType An enum that specifies the output on the trigger to |
| * represent. |
| */ |
| AnalogTriggerOutput::AnalogTriggerOutput(const AnalogTrigger& trigger, |
| AnalogTriggerType outputType) |
| : m_trigger(trigger), m_outputType(outputType) { |
| HAL_Report(HALUsageReporting::kResourceType_AnalogTriggerOutput, |
| trigger.GetIndex(), static_cast<uint8_t>(outputType)); |
| } |
| |
| AnalogTriggerOutput::~AnalogTriggerOutput() { |
| if (m_interrupt != HAL_kInvalidHandle) { |
| int32_t status = 0; |
| HAL_CleanInterrupts(m_interrupt, &status); |
| // ignore status, as an invalid handle just needs to be ignored. |
| m_interrupt = HAL_kInvalidHandle; |
| } |
| } |
| |
| /** |
| * Get the state of the analog trigger output. |
| * |
| * @return The state of the analog trigger output. |
| */ |
| bool AnalogTriggerOutput::Get() const { |
| int32_t status = 0; |
| bool result = HAL_GetAnalogTriggerOutput( |
| m_trigger.m_trigger, static_cast<HAL_AnalogTriggerType>(m_outputType), |
| &status); |
| wpi_setErrorWithContext(status, HAL_GetErrorMessage(status)); |
| return result; |
| } |
| |
| /** |
| * @return The HAL Handle to the specified source. |
| */ |
| HAL_Handle AnalogTriggerOutput::GetPortHandleForRouting() const { |
| return m_trigger.m_trigger; |
| } |
| |
| /** |
| * Is source an AnalogTrigger |
| */ |
| bool AnalogTriggerOutput::IsAnalogTrigger() const { return true; } |
| |
| /** |
| * @return The type of analog trigger output to be used. |
| */ |
| AnalogTriggerType AnalogTriggerOutput::GetAnalogTriggerTypeForRouting() const { |
| return m_outputType; |
| } |
| |
| /** |
| * @return The channel of the source. |
| */ |
| int AnalogTriggerOutput::GetChannel() const { return m_trigger.m_index; } |