Recalibrate comp bot after SFR 2019
It was tensioned again, so here we go.
Change-Id: Ie9558d75429ae4db365eecc7da26666650bc2b88
diff --git a/y2019/constants.cc b/y2019/constants.cc
index ee8c8e8..aac1f95 100644
--- a/y2019/constants.cc
+++ b/y2019/constants.cc
@@ -185,8 +185,8 @@
intake->zeroing_constants.measured_absolute_position = 1.860016;
- wrist_params->zeroing_constants.measured_absolute_position = 0.163840;
- wrist->potentiometer_offset = -4.257454;
+ wrist_params->zeroing_constants.measured_absolute_position = 0.164498;
+ wrist->potentiometer_offset = -4.257454 - 0.058039;
stilts_params->zeroing_constants.measured_absolute_position = 0.066843;
stilts->potentiometer_offset = -0.015760 + 0.011604 - 0.061213 + 0.006690;